CONTROLLERS
เครื่องควบคุมอุณภูมิ
เครื่องควบคุมที่ทำหน้าที่ในการประมวลผลสัญญาณ in put จาก Temp เซนเซอร์วัดอุณหภูมิ และสั่งงาน out put เพื่อไปควบคุมอุปกรณ์ในการเพิ่มหรือลดอุณภูมิ รวมถึงสามารถต่อเข้ากับระบบควบคุมแบบใหม่ได้
PRODUCT / MODEL
Digital Indicating Controllers
Model : LT23A, LT35A/LT37A, LT45A/LT47A
Features
Digital controller using PID control which adopted new algorithm “High Performance PID” and “Overshoot Suppression Function”. Each model can set various parameters and also acquire data by using loader software.
- Enriched input type (LT23A Series) / Universal Input (LT35A/LT37A, LT45A/LT47A Series)
- Outstanding controllability
- Various input/output signal (optional) are available
- Terminal block type and socket type are available (LT23A Series)
- Conformance to international safety standards
- Load software is available (sold separately)
Digital Indicating Controllers
Model : DB1000/DB2000 Series
Features
High accuracy of ±0.1% & control cycle of approximately 0.1 seconds.
Various function including universal input and multiple setting values (8 types) are provided as standard.
- Large easy-to-view 5 digit display , with 2 colors of casing available
- Highly-functional operation screen and setting screen
- Outstanding controllability
- Conforming to international safety standards and CE Marking, UL-CSA
- Motor feedback value indication enabled in ON-OFF servo output type
ON-OFF Servo Unit
Model : DU500 Series
Features
- Covert current output signal from the controller to on-off servo signal to drive the actuator e.g. control motor.
- Open loop method standard equipped.(Control by full opened time full ⬄closed time instead of feedback input).
- Manual output value settable at auto/manual switching. Manual output value is selectable from either output value at switching or preset manual. A/M switching can be also done by exterior signal (option).
MANUAL UNIT
Model : DU600 Sesies
Features
- Receive 4 to 20mADC current output signal from the controller and output that signal isolated (AUTO) or manually output the arbitrary value (MAN)
- Open loop method standard equipped. (Control by full opened time full ⬄ closed time instead of feedback input).
- Manual output value settable at auto/manual switching. Manual output value is selectable from either output value at switching or preset manual. A/M switching can be also done by exterior signal (option).
Digital Indicator with Alarm
Model : DI5000 Series
Features
Compact Design digital indicator with alarm which has sampling rate about 0.1 seconds. Equipped with various functions such as multi range input of thermocouples, resistance thermocouple, DC voltage/current and alarm outputs.
- Easy-to-see wide view angle 5digits/11 segment display
- Various input/output function, 29 multi range input
- High measuring accuracy +/-0.1%
- Abundant type of alarm, max. 4 alarm output
Digital Program Controllers
Model : KP1000/KP2000 Series
Features
Digital program controller with the indicating accuracy of ±0.1% and the control cycle of approx 0.1 seconds and maximum 19 program patterns(KP1000) and maximum 30 program patterns (KP2000) (maximum 19 steps/pattern). Various function including the whole program pattern display screen and universal input are provided as standard.
- Large easy-to-view 5 digit display. Easily identifiable pattern progress display.
- Highly-functional operation screen and setting screen & Outstanding controllability.
Graphic Program Controllers
Model : DP1000G Series
Features
- Graphic program controller with high visibility 5.6” TFT color LCD display, universal input.
- Easy program pattern setting on graphic screen. Maximum 200 types of program pattern (Maximum 4000 steps) are stored and performance pattern is selectable.
- Control cycle of 0.1sec, 5 digits display, high speed & high accuracy of ±0.1%
- Parameter setting per step. Storing settings in CF card
Graphic Program Controllers
Model : DP3000G Series
Features
- Graphic program setter employed high visibility 5.6” TFT color LCD display.
- Easy program pattern setting on graphic screen. Maximum 200 types of program pattern (Maximum 4000 steps) are stored and performance pattern is selectable.
- Setting output can be selectable from high accuracy analog output (DC current/voltage) and digital output with no setting errors using communications.
- Abundant external input/output functions. Time signal setting per step. Storing settings in CF card.
SKILLFULL INSTALLATION TEAM
มีทีมงานติดตั้งมืออาชีพ
ทีมงานติดตั้งมืออาชีพที่มากด้วยประสบการณ์ สามารถติดตั้งงานได้อย่างเรียบร้อย เป็นระบบ เพื่อป้องกันความล่าช้า หรือความผิดพลาดที่เกิดขึ้นจากการติดตั้ง
AFTER-SALE
SERVICE
มีบริการหลังการขาย
ไม่ว่าจะเป็นเรื่องของการ MAINTENANCE หรือการแก้ไขปัญหาหน้างาน เรามีทีมงานที่ได้รับการฝึกฝนให้ทำงานอย่างเป็นระบบ วิเคราะห์และแก้ไขปัญหาได้อย่างตรงจุด บริการได้รวดเร็วและมีมาตรฐาน
CALIBRATION
SERVICE
มีบริการสอบเทียบ
มีบริการสอบเทียบเครื่องมือ วัดจากโรงงาน